Hi Mohamed
regarding Error E 071 of SC-810 control please check :
1- thread trimmer cam correct adjusted or not.
2- there is a lot of thread into motor pulley or machine pulley.
3- if error E 071 coming immediately when turn power ON means problem inside control box, to confirm that please put working control box on machine , if error remove means problem at control box.
best regards
ASHRAF ABOZID
aabozid@hotmail.com
CAIRO - EGYPT
hi there
E810 in sc500,sc800,sc810 means low voltage coming.
chaeck power supply-check white resistanceback insaide control box.
if resolved ok if not please email me for more information.
best regards
ashraf abozid aabozid@hotmail.com
CAIRO - EGYPT
hi there concern ERROR ( E071 ) means Disconnection o motor output connector. please check the motor output connector for loose connection and disconnection. otherways means IPM module is defective. if you need more help please contact me. BEST REGARDS ASHRAF ABOZID aabozid@hotmail.com
×