Question about Art Cool LA181CNW Split System Air Conditioner
...error code is CH46 (LG split klima). Why is this happened? Thank you! WHERE SHOULD THE SUCTION PIPE SENSOR BE CH46 indicates that the suction pipe sensor is missing orfaulty. If misplaced, place it ...
Question about LS240CE Split System Air Conditioner
error code flashing ch46 do you have a list of codes and what they mean. CH-46.Outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°
ERROR CH46 if you have multiple unit running from one compressor then you get this code when you set one unit to heat and another unit to cool. All units running from a single compressor need to be in
Question about Art Cool LA121HNP Split System Air Conditioner
...remote control. How can fix it? ERROR CH46: Outdoor unit suction sensor fault. Disconnect from PCB and measure resistance. 10 kOhm at 10°C and 4 kOhm at 30°C. If OK replace PCB, if not replace
Usually answered in minutes!
2,518 Questions
1,056 Questions
713 Questions
416 Questions
354 Questions