Questions & Answers for: ih codes

Question about DPSB613EDWW Electric Dryer

1 Answer

Letters IH on estimated time remaining display Only in the More Dry mode, when dryer is turned on, the letters IH appear in the time remaining display. The letters IH alternate flashing with the time ...

Ad

Question about DPSB613EDWW Electric Dryer

3 Answers

...(3) Check if the harnesses of the main and edge thermistors are open circuited. 2. Check the IH board and IH coil (1) Check if the IH coil is broken. (2) Check if the connector of the IH coil ...

Ad

Question about Estudio 200L Copier

2 Answers

...Check if the harnesses of the main and edge thermistors are open circuited.2. Check the IH board and IH coil(1) Check if the IH coil is broken.(2) Check if the connector of the IH coil is ...

...Check if the harnesses of the main and edge thermistors are open circuited.2. Check the IH board and IH coil(1) Check if the IH coil is broken.(2) Check if the connector of the IH coil is ...

Question about Estudio 200L Copier

2 Answers

...codes out but the equipment is in working order. replaced PWA relay boards, and high voltage units. still no fix. If 1st time occur, u can just go to 08-400, reset the value to "0" then restart the ...

Question about Estudio 200L Copier

2 Answers

...Check if the harnesses of the main and edge thermistors are open circuited.2. Check the IH board and IH coil(1) Check if the IH coil is broken.(2) Check if the connector of the IH coil is ...

Question about e-Studio 205 Copier

1 Answer

...Check if the harnesses of the main and edge thermistors are open circuited.2. Check the IH board and IH coil(1) Check if the IH coil is broken.(2) Check if the connector of the IH coil is ...

...Check if the harnesses of the main and edge thermistors are open circuited.2. Check the IH board and IH coil(1) Check if the IH coil is broken.(2) Check if the connector of the IH coil is ...

Question about COPIERS E-STUDIO 520 Copier

2 Answers

...the message... 08-400 "0"If occur again, u need to check the fuser probable, such as themistor, IH board, connectors and etc... If 1st time occur, u can just go to 08-400, reset the value to "0" ...

Question about e-Studio 202L Copier

1 Answer

...(3) Check if the harnesses of the main and edge thermistors are open circuited. 2. Check the IH board and IH coil (1) Check if the IH coil is broken. (2) Check if the connector of the IH coil ...

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Dryers Experts

AskDyson
AskDyson

Level 3 Expert

2572 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

73784 Answers

Brad Brown

Level 3 Expert

19190 Answers

Are you a Dryers Expert? Answer questions, earn points and help others

Answer questions