...IH alternate flashing with the time remaining based on the sensor system estimate of drying time. Can't find the error code (or information code) IH anywhere in the manual. Can you help? 1H = 1 ...
...error code C44, it indicates Heater abnormality. If 1st time occur, u can just go to 08-400, reset the value to "0" then restart the machine. If happen again, then u need to check the thermistor. ...
...error....Really need a tech to fix this...could be bad wall voltage....or the thermostat in the IH unit...or the fuse in the IH unit...or the logic board.... e.studio 212 problems(error
...error code c44 e studio 163 C44 Abnormal fuser after abnormality judgment 1,2.3. Check the thermistors, IH control board, IH coil and LGC board Check the above components following the procedure 1, 2 ...
...error code appears. what is the possible defective parts? Hi how are you this is jack ...(jack_pak@hotmail.com).. Dear follow the procedure [C440] Fuser abnormality after abnormality judment. When ...
error code, need to replace fuser unit BR If 1st time occur, u can just go to 08-400, reset the value to "0" then restart the machine. When this code not cleat 08-400 then check these all thengs.
Question about e-Studio 232 Black and White Copier
error is c440 then do the following switch off the machine If 1st time occur, u can just go to 08-400, reset the value to "0" then restart the machine. When this code not cleat 08-400 then check these
Question about e-Studio 350 Copier
error code 440 how do i reset that and what is the solution to fix it? If 1st time occur, u can just go to 08-400, reset the value to "0" then restart the machine. When this code not cleat 08-400
...error...Clear the message... 08-400 "0"If occur again, u need to check the fuser probable, such as themistor, IH board, connectors and etc... If 1st time occur, u can just go to 08-400, reset the ...
...IH input voltage error • While the IH heater was ON, input power was at the high voltage detection value or over for more than the predetermined period of time. • While the IH heater was ON, input ...