Questions & Answers for: intermatic t103 timer working

Question about T103 Indoor 120-Volt 40-amp Timer Switch-Double Pole/Single Thro

1 Answer

Intermatic T103 - It was working. However, now I Intermatic T103 - It was working. However, now I can hear the ticking, but nothing moves. Intermatic has had an issue with the main drive gear striping

Ad

Question about T103 Indoor 120-Volt 40-amp Timer Switch-Double Pole/Single Thro

1 Answer

...T103. At times when "on" trip is engaged it just sits there and clicks. Removed set back up. Trip turned (water heater) on but "off" trip doesn't work i.e. Never shuts off. An idea what's wrong? ON ...

Ad

Question about & Indoor/Outdoor Rain Tight Timer

1 Answer

...Intermatic-timer.html#T103 Add a comment for more free help. Also take advantage of fixya phone service. For a price, expert speaks with you over phone while you work on timer or any do-it-yourself ...

Question about T103 Indoor 120-Volt 40-amp Timer Switch-Double Pole/Single Thro

1 Answer

...T103 Intermatic timer has 120Volt clock motor and can control 120V or 240V Loads. Wiring for timer is shown on following link: http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T103 ...

Question about T103 Indoor 120-Volt 40-amp Timer Switch-Double Pole/Single Thro

1 Answer

T103 Intermatic 120V timer. Sounds like you wired the timer wrong: Timer has 120V clock motor and requires Hot from breaker on terminal 1, and Neutral from breaker on terminal A. This will power clock

Question about T103 Indoor 120-Volt 40-amp Timer Switch-Double Pole/Single Thro

1 Answer

...Intermatic-timer.html#T103 3) GE has terminals 1 and L which are connected by brass bridge. If brass bridge is removed, add a jumper wire and connect terminals 1 and L GE has terminals 1-L X 2 4) ...

Question about & Indoor/Outdoor Rain Tight Timer

1 Answer

...and manual. http://waterheatertimer.org/How-to-wire-T104-Intermatic-timer.html#T103 Open following link for replacement parts list: ...

Question about T103 Indoor 120-Volt 40-amp Timer Switch-Double Pole/Single Thro

1 Answer

...Intermatic-timer.html#T103 2) Add a comment for specific help with wiring, and I will respond. Give details of pump voltage, and description of each wire. 3) To fix old timer, Replace 3-watt, 120Volt ...

Question about T103R 120-Volt 40-amp Timer Switch-Double Pole / Single Throw

1 Answer

...http://waterheatertimer.org/How-to-troubleshoot-Intermatic-timer.html Add comment and say if this is new timer or old timer that stopped ...

Question about T103 Indoor 120-Volt 40-amp Timer Switch-Double Pole/Single Thro

0 Answer

T103, I tried to manually turn the swich inside the T103 but still the light does not turn on The timer may be working, but the switch has failed. This is a common failure of electro-mechanical timers

Not finding what you are looking for?

Ask a Question

Usually answered in minutes!

Top Hardware & Accessories Experts

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

73781 Answers

Brad Brown

Level 3 Expert

19190 Answers

Steve Pack
Steve Pack

Level 3 Expert

7214 Answers

Are you a Hardware & Accessories Expert? Answer questions, earn points and help others